Field Check Pro

Field Check Pro

Professional coating inspection and reporting

Coating Inspection ReportRpt # FCP-0001 · Rev 0

Looking for a coating inspection?

Inspector
AMPP CIP L2
Spec ref
ITP-COAT-01
Stage
Final DFT
CheckRequiredMeasuredResult
Surface prepSSPC-SP 10NACE No. 2PASS
Anchor profile2.5–3.5 mils3.1 milsPASS
Rel. humidity≤ 85 %62 %PASS
Surface − dew pt≥ 5 °F14.2 °FPASS
DFT (SSPC-PA 2)5.0–7.0 mils6.2 milsPASS
ApprovedVisit fieldcheckpro.ca
Field Check Pro app

Want the inspection app?

Field Check Pro · Productivity

Technical data sheets, barcode scanning, JHA, QA checks and PDF reports.

Free for 14 daysStart free trial Already have the app? Sign in